Illumination/Observation System: | D/8(Diffused Lighting, 8 Degrees Observe Angle) |
---|---|
Size of Integrating Sphere: | Φ40mm |
Wavelength Range: | 400~700nm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | CS-820 |
Measurement Condition | Reflection: d/8(Diffused lighting, 8 degrees receiving) Compatible with SCI/SCE Measurement ISO7724/1,DIN5033 Teil7,JIS Z8722 condition C,CIE No.15,ASTM E1164) Transmission d/0(Diffused lighting, Vertical direction receiving) |
Size of integrating sphere | Φ15.2cm, Alvan diffused reflection surface coating |
Illumination Light source | CLEDs(entire wavelength balanced LED light source) |
Sensor | dual light path sensor array |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflectivity range | 0-200% |
Reflectivity resolution | 0.01% |
Observation angle | 2°/10° |
Measurement light source | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 CWF,U30,DLF,NBF,TL83,TL84 |
Data being displayed | SPD distribution/data, sample's color values, color difference values/graph, pass/fail results, color error tendency, history data color simulation, manual input standard sample, generate measurement report |
Measurement time interval | 2 seconds |
Reflection Aperture | Large Aperture (LAV):2.54cm (=1inch) |
Medium Aperture (MAV):1.5cm(=0.6inch) | |
Small Aperture (SAV):0.75cmx1.0cm(0.3inch x 0.4inch) | |
Very Small Aperture (VSAV):0.3cmx0.8cm(0.12inch x 0.31inch) | |
Color space | CIE-L*a*b,L*C*h,CIE-L*u*v,XYZ,Yxy,Transmittance, Hunterlab, Munsell MI,CMYK, RGB,HSB |
Color difference formulas | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00 ΔEab(Hunter),555color classification |
Other colorimetric indices | WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00,CIE,Ganz),Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner |
Repeatability | light splitting reflectivity: standard deviation within 0.08% |
color values:ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals,Maximum:0.03) | |
Interface | USB |
Data storage | mass storage |
Light source longevity | 5 years, 1.5 million tests |
Size | 583*330*304mm(L*W*H) |
Work temperature range | 15ºC-32ºC (60°F-90°F) |
Relative Humidity | 0ºC to 45ºC,relative humidity 80% or below(at 35°C ), no condensation |
Standard accessories | AC power line, color management software, drive software, USB cable, black/white calibration tube, 40*10 cuvette, cuvette support, testing report |
Optional | 40x40 cuvette |