Elisa Reader (DNM-9606)

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 3000 PCS/ Year
Payment Terms: T/T
Basic Info
  • Model NO.: DNM-9606
  • Range of Working Wavelength: 400nm to 800nm
  • Trademark: ZSIMC
  • Specification: 520*410*255mm
  • HS Code: 9027809900
  • Measurement System: 8-Channel Optical System
  • Standard: 4 Filters (405,450,492,630nm)
  • Transport Package: Export Packing
  • Origin: China
Product Description
DNM-9606 Microplate (ELISA) Reader
 
 
 
Application 
It mainly used to immunity detection and microanalysis in chemistry and biochemistry in hospital and relevant clinical laboratory.
 
Principle and structure 
1. Working principle 
The instrument adopts photoelectric colorimetry with ELISA reagent to test. It tests the absorbance of standard liquid and detecting liquid firstly, and set out the content of detecting substance in sample liquid through analysis and calculation.
2. Structure features
The instrument has two main components: the mainframe and the printer.
The mainframe is composed of optic system, 8-channel detection system, singlechip system and enzymatic plate driving system.
The instrument can detect enzymatic plate that has 96 or 48 wells.
 

Technical specifications
1. Functions
1) Main functions for DNM-9606 microplate reader:
a. Instrument can do self-check in boot-strap.
b. Instrument can select filter automatically.
c. Instrument has the function of vibration.
d. Instrument can communicate and it has two protocols to choose.
e. Instrument can store 126 test-programs, which can be called in test.
f. Instrument can store 126 groups of calibrating parameters and curve, and it also can store 105 groups of testing data for full-plate.
g. Instrument has single and dual wavelength test to be selected by user.
h. Instrument has the analysis function of absorbance, qualitative and quantitative. Thereinto qualitative test has two methods, which respectively is critical value and critical value adjustment, and you can setup the area of gray scale at will; the quantitative test has nine methods, which respectively is linear regression, semi-logarithm, full-logarithm, exponential regression, ratio regression, quadratic equation, point to point, ratio semi-logarithm and Logit-log curve.
i. Instrument can output ten kinds data, which is respectively absorbance, critical value, feminine and masculine result, semi-quantitative value, concentration, normal reference value, judgment result, QC data, QC drawing and calibrating curve.
j. Instrument can randomly store, inquire and print the QC data and QC curve in month for five items.
 
2) The main functions of microplate reader for DNM-9606 as follow:
a. Instrument can do self-check in boot-strap.
b. Instrument can select filter automatically.
c. Instrument has the function of vibration.
d. Instrument can communicate and it has two protocols to choose.
e. Instrument can store 126 test-programs, which can be called in test.
f. Instrument can store 126 groups of calibrating parameters and curve, and it also can store 105 groups of testing data for full-plate.
g. Instrument has single and dual wavelength test to be selected by user.
h. Instrument has the analysis function of absorbance, qualitative and quantitative. Thereinto qualitative test has two methods, which respectively is critical value and critical value adjustment, and you can setup the area of gray scale at will; the quantitative test has nine methods, which respectively is linear regression, semi-logarithm, full-logarithm, exponential regression, ratio regression, quadratic equation, point to point, ratio semi-logarithm and Logit-log curve.
i. Instrument can output ten kinds data, which is respectively absorbance, critical value, feminine and masculine result, semi-quantitative value, concentration, normal reference value, judgment result, QC data, QC drawing and calibrating curve.
j. Instrument can randomly store, inquire and print the QC data and QC curve in month for five items.
 
Specifications
Measurement System8-Channel optical system
Wavelength Range400nm~800nm
Filters  Standard:4 filters (405, 450, 492, 630nm)
Totally 10 filters can be installed
Measurement Range 0.000~4.000Abs
Photometric Accuracy±0.01Abs (0.001~1.500Abs)
Repeatability≤0.5%
Stability≤±0.005Abs
Linearity<±1% (0.001~1.500Abs)
Display7.5" Touch Screen
System Win 7 and Win XP, LIS, HIS
Calculation MethodTwo-point, Linear regression method, Semi logarithmic method, Ratio log method, Full log method, Exponential regression(LogA-C), Logit-Log, Point to Point(Broken line method), Four parameter method, Two square curve, Three square curve and Three square spline
PrinterBuilt-in Thermal Printer
Data CommunicationRS232
Power SupplyAC220V/110V±22V  50HZ/60HZ±1HZ
Dimension420x350x178 mm
Weight9kg
 
 